Dust Control

Road Stabilization

Erosion Control

Environmental, Health & Safety Information

UNCONFINED COMPRESSIVE STRENGTH MEASUREMENTS 

PennzSupress® D Laboratory Testing
American Materials Recycled Asphalt
LAW Project No. 60133-6-5352
December 16, 1996

 

Sieve Analysis ASTM C136

 

Control

PennzSuppress® Treated Samples

% Passing No. 1 3/4"

100

n/a

% Passing No. 1 1/2"

100

n/a

% Passing No. 1"

97.1

n/a

% Passing No. 3/4"

91.8

n/a

% Passing No. 1/2"

82.7

n/a

% Passing No. 3/8"

72.5

n/a

% Passing No. 4

42.4

n/a

% Passing No. 8

27.2

n/a

% Passing No. 10

25.5

n/a

% Passing No. 40

9.2

n/a

% Passing No. 80

1.8

n/a

% Passing No. 100

1.0

n/a

% Passing No. 200

0.3

n/a

 

Proctor Test ASTM D1557-78D

 

Control

PennzSuppress® Treated Samples

Maximum Dry Density, pcf

127.6

130.0

Optimum Moisture Content, %

7.7

9.8

** Maximum Dry Density, pcf

n/a

127.2

*Optimum Moisture Content

n/a

7.8

 

Plasticity Index ASTM 4318

 

Control

PennzSuppress® Treated Samples

 

non plastic

n/a

 

Unconfined Compressive Strength (psi), ASTM D1663
All Samples Cured for 7-Days at 40 Degrees C

Application Rate

Individual Strength (psi)

Average Strength (psi)

Control

150

 

Control

125

140

1:1 dilution; 1.5 gals./sq. yd.

175

 
1:1 dilution; 1.5 gals./sq. yd

165

170

2:1 dilution; 1.5 gals./sq. yd

150

 
2:1 dilution; 1.5 gals./sq. yd.

160

155

4:1 dilution; 1.5 gals./sq. yd.

140

 
4:1 dilution; 1.5 gals./sq. yd.

165

155

Picture

                                             