Dust Control

Road Stabilization

Erosion Control

Environmental, Health & Safety Information

UNCONFINED COMPRESSIVE STRENGTH MEASUREMENTS 

PennzSupress® D Laboratory Testing
Amarillo Area Caliche
LAW Project No. 60133-6-5352
December 19,1996

Sieve Analysis ASTM C136

 

Control

PennzSuppress® Treated Samples

% Passing No. 1 3/4"

100

n/a

% Passing No. 1 1/2"

100

n/a

% Passing No. 1"

100

n/a

% Passing No. 3/4"

100

n/a

% Passing No. 1/2"

80.4

n/a

% Passing No. 3/8"

74.6

n/a

% Passing No. 4

60.9

n/a

% Passing No. 8

51.8

n/a

% Passing No. 10

50.6

n/a

% Passing No. 40

35.8

n/a

% Passing No. 80

26.2

n/a

% Passing No. 100

23.0

n/a

% Passing No. 200

13.7

n/a

 

Proctor Test ASTM D1557-78D

 

Control

PennzSuppress® Treated Samples

Maximum Dry Density, pcf

115.1

116.3

Optimum Moisture Content, %

13.4

12.2

 

Plasticity Index, ASTM 4318

 

Control

PennzSuppress® Treated Samples

 

16

n/a

 

Unconfined Compressive Strength (psi), ASTM D1663
All Samples Cured for 7-Days at 40 Degrees C

Application Rate

Individual Strength (psi)

Average Strength (psi)

Control

480

 

Control

575

530

4:1 dilution; 1.0 gals./sq. yd.

1075

 
4:1 dilution; 1.0 gals./sq. yd.

1155

1115

2:1 dilution; 1.5 gals./sq. yd.

1010

 
2:1 dilution; 1.5 gals./sq. yd.

1040

1025

4:1 dilution; 1.5 gals./sq. yd.

995

 
4:1 dilution; 1.5 gals./sq. yd.

930

965

Picture

                                            

[Home]      [American Refining Group]